  emi: meets fcc / meets ce comply with indoor/outdoor waterproof (ip 67) warranty: 5 years (refer to linkcom warranty policy) rohs compliant 4.6 output current tolerance efficiency o/p noise(p-p,v) 84% > 0.95 @ 115 vac / > 0.9 @ 230 vac at full load 90-305 vac, 127-431 vdc, normal: 100-277 vac 0.75 ma / 132 vac / 60 hz turn on delay time reference: www.linkcom.com.tw withstand voltage dimension (l*w*h) (2) all specifications typical at 25 , unless otherwise noted, at normal line and load. (3) ripple and noise measured directly at pins/terminals at nom. load, 0.1uf bypass and 47uf electrolytic, pk-pk at 20mhz bandwidth. (4) specified for free-air convection cooling. (5) minimum load is not required for proper operation . (6) 100% production tested. 158 * 58 * 39.4 mm 6.22 * 2.28 * 1.55 inch please contact sales@linkcom.com.tw , sales@linkcomusa.com for more information (1) all parameters specified at 230 vac input unless otherwise noted. ac current emi -20 ~ +60 isolation resistance features: scp, ovp and otp will restart automatically after the fault condition is removed cold start 50 a @ 230 vac over voltage protection leakage current range: 47-63 hz, normal: 50-60 hz electrical specification < 20% @ 277 vac full load 3 s at full load 115 vac / 230 vac inrush current (max.) input voltage range meets fcc part15 / meets ce en55015 na na 60w led power supply constant current mode na safety operating temp. storage temp. relative humidity over current protection 60-lcc series 42-48 33-42 33-36 product specification 1.7 lccea060u172-00 lccea050u432-00 -40 ~ +80 10% to +90%, non-cond. ul 8750 input frequency active power factor 9-12 0.8 a / 115 vac 0.4 a / 230 vac over temp. protection thd short circuit protection lccea060u132-00 lccea060u142-00 4.3 62.4 output current(a) model dc output power(w) dc output voltage(v) 1.4 58.8 61.2 51.6 ac input 90~305 vac nominal power factor: > 0.95 @ 115 vac / > 0.9 @ 230 vac @ full load protection: scp / ovp / ocp 4.2 2 5% 86% 1.3 86% high operating ambient temp.: -20 ~ +60 surge protection: l-n 1 kv, l/n-fg 2 kv safety: ul 5% 5% 86% 3.6 5% www.linkcom.com.tw for more information, please contact with: sales@linkcom.com.tw linkcom manufacturing co., ltd. 5f., no. 127, ln. 235, baoqiao rd., xindian dist., new taipei city 231-45, taiwan ? t: +886-2-8919-1380 ? f: +886-2-8919-1370 ? www.linkcom.com.tw
60w led power supply constant current mode 60-lcc series www.linkcom.com.tw for more information, please contact with: sales@linkcom.com.tw reference: www.linkcom.com.tw dimensions tc lccea060u142 as tc max. reference linkcom manufacturing co., ltd. 5f., no. 127, ln. 235, baoqiao rd., xindian dist., new taipei city 231-45, taiwan ? t: +886-2-8919-1380 ? f: +886-2-8919-1370 ? www.linkcom.com.tw
60w led power supply constant current mode 60-lcc series www.linkcom.com.tw for more information, please contact with: sales@linkcom.com.tw output current vs. load (lccea060u132-00) efficiency vs. load (lccea060u132-00) thd vs. load (lccea060u132-00) 1.290 1.300 1.310 1.320 86.0% 88.0% 90.0% 92.0% 94.0% 96.0% 98.0% 100.0% 102.0% output current (a) load(%) output current vs. load vin=100 vin=120 vin=200 vin=230 vin=277 80.0% 82.0% 84.0% 86.0% 88.0% 90.0% 86.0% 88.0% 90.0% 92.0% 94.0% 96.0% 98.0% 100.0% 102.0% efficiency (%) load (%) efficiency vs. load vin=100 vin=120 vin=200 vin=230 vin=277 0% 5% 10% 15% 20% 86.0% 88.0% 90.0% 92.0% 94.0% 96.0% 98.0% 100.0% 102.0% thd (%) load (%) thd vs. load vin=100 vin=120 vin=200 vin=230 vin=277 linkcom manufacturing co., ltd. 5f., no. 127, ln. 235, baoqiao rd., xindian dist., new taipei city 231-45, taiwan ? t: +886-2-8919-1380 ? f: +886-2-8919-1370 ? www.linkcom.com.tw
60w led power supply constant current mode 60-lcc series www.linkcom.com.tw for more information, please contact with: sales@linkcom.com.tw pf vs. load (lccea060u132-00) 0.75 0.80 0.85 0.90 0.95 1.00 86.0% 88.0% 90.0% 92.0% 94.0% 96.0% 98.0% 100.0% 102.0% power factor load (%) pf vs. load vin=100 vin=120 vin=200 vin=230 vin=277 linkcom manufacturing co., ltd. 5f., no. 127, ln. 235, baoqiao rd., xindian dist., new taipei city 231-45, taiwan ? t: +886-2-8919-1380 ? f: +886-2-8919-1370 ? www.linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of 60W-LCCEA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X